当前位置:首页 > 文献互助 > 互助详情

Are Expensive Materials Really Necessary to Perform Transobturator Tape Operations?复制

用户w1FFZhfa_Gk4 1个月前 90 10 已完结

1. 系统已在2026-10-17 16:08:30对应助文件进行删除

2. 如有需要请重新发布求助信息

注: 所有应助的资源仅供学习交流使用, 不得违反相关法律法规

DOI: 10.4328/jcam.865复制

文献链接: https://archive.org/download/are-expensive-materials-really-necessary-to-perform-transobturator-tape-operations/KATD-865.pdf复制

其他信息:

出版社: Bayrakol Medical Publishing
Our aim was to assess the cost and effectiveness of transobturatuar tape (TOT) devices, made with tailored polypropylene mesh by the surgeon during the operation. Material and Method: Between May 2006 and June 2009, a total of 41 women underwent TOT procedure. The cure of SUI was defined as no urine leakage at cough test and not reporting any event of urinary incontinence. Result: The mean operative time was 22.3±5.3 minutes (range 14 to 33 minutes). No peroperative complications were recorded. Minor complications such as urinary tract infections, de novo urgency and postoperative fever occurred in 4.8% of patients. Two patients (4.8%) showed urinary retention. Overall 37 (90.2%) and 32 (78%) of patients were continent after 12 and 24 months, respectively. Discussion: TOT procedures performed with polipropilene mesh and no.1 silk line are as safe and effective as performing this operation with commercial TOT devices where as they are less expensive.

互助时间线

2026-10-10 16:16:06 [完结求助]

楼主确认了用户p8owQWCueN6Y应助的文件是正确的, 求助状态变成 已完结

2026-10-10 16:08:30 [上传文件]

用户p8owQWCueN6Y上传了文件(pdf 627.88 KB), 求助状态变成 待确认

2026-10-10 15:03:24 [发起求助]